福祿克Fluke 190-504彩色數(shù)據(jù)示波表
福祿克Fluke 120B 系列 ScopeMeter?工業(yè)用手持式示波表
福祿克Fluke-190-204/S ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-502 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-202 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-102 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-104 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-062 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke OptiFiber? Pro?OTDR系列
福祿克Fluke CertiFiber?光纖損耗測試套件
福祿克Fluke SimpliFiber? Pro光功率計和光纖測試儀
福祿克Fluke Fiber QuickMap?多模光纖距離和故障定位儀
福祿克Fluke Fiber OneShot? PRO光纖測試儀
福祿克Fluke VisiFault? Visual Fault Locator電纜連通性測試儀
福祿克Fluke MultiFiber? Pro光功率計及光纖測試工具包
福祿克Fluke FI-7000 FiberInspector? Pro光纖顯微攝像機(jī)
NetAlly LinkRunner? G2智能有線網(wǎng)絡(luò)測試儀
NetAlly LinkRunner? AT網(wǎng)絡(luò)自動測試儀
NetAlly OneTouch? AT G2網(wǎng)絡(luò)性能測試儀
NetAlly EtherScope nXG便攜式網(wǎng)絡(luò)專業(yè)智能測試工具
NetAlly LinkRunner 10G高級以太網(wǎng)測試儀
福祿克Fluke LinkIQ?線纜+網(wǎng)絡(luò)測試儀
NetAlly LinkSprinter?口袋便攜式網(wǎng)絡(luò)測試儀
福祿克Fluke EtherScope II網(wǎng)絡(luò)通二代
福祿克Fluke 190-504彩色數(shù)據(jù)示波表
泰克Tektronix MDO3000混合域示波器
福祿克Fluke 120B 系列 ScopeMeter?工業(yè)用手持式示波表
福祿克Fluke-190-204/S ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-502 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-202 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-102 ScopeMeter?彩色數(shù)字示波表
福祿克Fluke-190-104 ScopeMeter?彩色數(shù)字示波表
洞察行業(yè)資訊 分享專業(yè)知識
洞察行業(yè)資訊 分享專業(yè)知識
全國統(tǒng)一服務(wù)熱線:
134 1039 1245
400-996-0787
0755-8399 9818
聯(lián)系郵箱:
sales@faxytech.com
聯(lián)系地址:
深圳市福田區(qū)華強北路華聯(lián)發(fā)大廈602室
If you have access to YouTube, you can click here to watch a video of this new feature in action.
In data centers where the shield is typically grounded at both ends, ANY wire map tester will report the shield as connected, even if it is not. That's because the shield test is a simple DC Resistance measurement. If the shield is open, it will find the remote unit using the building ground (earth).
The DSX CableAnalyzer offers a unique solution to this problem. It ties the four pairs together and then sends a differential signal down the cable treating the shield as the second conductor. This allows the DSX CableAnalyzer to view the shield in the time domain. So even if the patch panels are grounded, it will report the shield open, if indeed it is open you would see:
And since it is using time domain techniques, the distance to the open is given. In this example, we can see the patch panel at the near end is the issue.
The scenario above occurs when the technician grounds the connector on the non conductive side of the cable shield. The result is degraded Alien Crosstalk performance. Since users are told that shielded cabling systems do not need to be tested for Alien Crosstalk, one wonders how wide spread this issue is and whether users are getting the performance they paid for.
附加信息
If you only use the drain wire to connect the shield and that drain wire is greater than approx. 2 inches (5 cm), the DSX CableAnalyzer may report the shield as open. This is by design. Such a termination acts as an open circuit at the frequencies we are talking about here.